NEWS CENTER

News

Green development, innovative development, high-quality development

Information Disclosure of Hebei Heavy Cold Rolling Material Co., Ltd.


Release time:

May 13,2020

Information Disclosure of Hebei Heavy Cold Rolling Material Co., Ltd.

1. basic information

Name of (I): Hebei medium cold rolling material co., LTD

Address: Nanshugang Road, Bohai New District, Cangzhou City, Hebei Province

Legal Representative: Yang Shupeng

Name of major (II) pollutants: wastewater: COD, ammonia nitrogen, total nitrogen, pH, suspended solids, total phosphorus, petroleum, chroma, fluoride, total zinc, total copper, cyanide, total iron; Exhaust gas: particulate matter, sulfur dioxide, nitrogen oxides, hydrogen chloride, fluoride; Discharge mode: wastewater is discharged to the port city sewage treatment plant after treatment; Exhaust gas is discharged to the atmosphere through chimney after treatment; Emission concentration and total amount: (see annex)

(III)Record of environmental violations such as discharging pollutants in excess of discharge standards and discharging pollutants in excess of total control targets: No

(IV)Investment in environmental protection: 34.65 million yuan; Development and utilization of environmental protection technology and construction and operation of environmental protection facilities: According to the requirements of "three simultaneous" of environmental protection, the construction was approved by Hebei Provincial Environmental Protection Department on July 15, 2015, and the project acceptance was completed on July 15, 2017.

(V) the disposal and comprehensive utilization of wastes generated in the process of production and construction: hazardous wastes include: online waste liquid, sludge, zinc-containing wastes and waste mineral oil are all entrusted to qualified units for treatment; solid wastes: leftoffs, packaging materials such as waste banding of steel coils, dust collected by scale breaking and dust removal, zinc slag, etc. are all sold as raw materials. Domestic waste shall be handled uniformly by the local sanitation department.

Emergency plan for (VI) environmental pollution accidents, pollution accidents and losses caused by accidents: the preparation of the emergency environmental emergency plan report was completed in November 2018, and it was filed by Cangzhou Bohai New District Environmental Protection Bureau on December 23, 2018, with the filing number 130962-2018-050-M. No pollution accidents have occurred.

(VII) self-monitoring work and monitoring results (see annex)

(VIII) the payment of sewage charges (taxes) and the fulfillment of environmental and social responsibilities by enterprises: environmental protection taxes are paid in full every quarter.

Status of environmental protection training conducted by the (IX) for employees: monthly environmental protection knowledge training shall be conducted for employees and records shall be kept on file.

Other environmental information required by (X) laws and regulations: None

(11) Enterprises producing and using hazardous chemicals shall, in accordance with law, announce to the public the types of hazardous chemicals produced and used, hazard characteristics, relevant pollutant discharge and accident information, pollution prevention and control measures, etc:

Varieties of dangerous chemicals

Hazard characteristics

Pollutant emission

Accident Information

pollution prevention and control measures

Remarks

Hydrogen chloride

It can react with some active metal powder and release hydrogen. When it comes to cyanide, it can produce highly toxic hydrogen cyanide gas. It reacts with alkali and gives off a lot of heat. It is highly corrosive.

acid mist

None

Tightly sealed to provide adequate local exhaust and general ventilation. Operators must be specially trained and strictly abide by operating regulations. It is recommended that the operator wear a filtering gas mask (half mask), chemical safety goggles, anti-static overalls and rubber gloves. Prevent liquid leakage, volatile gas into the workplace and contact with the human body. Equipped with corresponding types and quantities of leakage emergency treatment equipment.

 

Natural gas

Fire and explosion hazards in case of heat source and open flame

Carbon monoxide, carbon dioxide

None

 

Attachments:

Serial Number

Monitoring point location

Monitoring items

Executive standard (mg/m3)

Monitoring results(mg/m3)

Whether it is up to standard

Remarks

1

Acid mist scrubber discharge outlet

Fluoride

6

2.36

Yes

 

Hydrogen chloride

15

11.7

Yes

 

2

acid regeneration alkali washing tower

Drain

Particulate matter

15

13.1

Yes

 

Sulphur dioxide

150

8.4

Yes

 

nitrogen oxide

300

25.6

Yes

 

Fluoride

9

1.25

Yes

 

Hydrogen chloride

30

9.3

Yes

 

3

Discharge port of acid regeneration plastic burning plate dust collector

Particulate matter

30

10.3

Yes

 

4

Pull the discharge port of the broken scale bag dust collector

Particulate matter

15

10.7

Yes

 

5

Oil mist separator drain

Oil Mist

20

--

 

Implementation pending publication of national monitoring methodologies

6

Discharge port of 400000-ton continuous annealing furnace

Particulate matter

15

--

 

Not Produced

Sulphur dioxide

150

--

 

nitrogen oxide

300

--

 

7

Discharge port of 400000-ton continuous alkali mist scrubber

alkali mist

10

--

 

Implementation pending publication of national monitoring methodologies

8

Discharge port of 200000 ton galvanizing annealing furnace

Particulate matter

15

--

 

Not Produced

Sulphur dioxide

150

--

 

nitrogen oxide

300

--

 

9

200000 tons of galvanized alkali mist washing tower discharge port

alkali mist

10

--

 

Implementation pending publication of national monitoring methodologies

10

Discharge port of 250000 ton galvanizing annealing furnace

Particulate matter

15

--

 

Not Produced

Sulphur dioxide

150

--

 

nitrogen oxide

300

--

 

11

250000 tons of galvanized alkali mist washing tower discharge port

alkali mist

10

--

 

Implementation pending publication of national monitoring methodologies

12

 

 

General waste water outlet

COD

70

38

Yes

 

ammonia nitrogen

5

1.45

Yes

 

Total nitrogen

15

1.39

Yes

 

suspended matter

30

8

Yes

 

total phosphorus

0.5

0.47

Yes

 

Petroleum

3

0.57

Yes

 

Fluoride

10

1.24

Yes

 

Total Zinc

2.0

0.373

Yes

 

Total Copper

0.5

0.330

Yes

 

Cyanide

0.5

ND

Yes

 

Total iron

10

0.17

Yes

 

pH

6-9

7.15-7.33

Yes

 

Approved total

Exhaust gas: 11.189 tons of particulate matter, 1.244 tons of sulfur dioxide and 36.836 tons of nitrogen oxides

Wastewater: COD 70.83 tons, ammonia nitrogen 5.312 tons, total nitrogen 78.75 tons

Total emissions

Waste gas: particulate matter: 3.98 tons, sulfur dioxide: 0.57 tons, nitrogen oxides: 1.72 tons

Wastewater: COD:14.72 tons, ammonia nitrogen: 0.54 tons, total nitrogen: 0.56 tons